The TPN House Service Cutout are designed for 60/80/100A rating complying with BS 7657:1993 and ESI 12-10. The housing is of DMC with a quality finish to ensure accuracy in the various parts for interchangeability. All the terminal blocks are of Brass duly Tin plated, fitted with two large pinching screws per conductor. The TPN House Service Cutout carries designed for standard BS 88 / BS 1361 fuse links and standard copper contacts having uniform pressure to ensure effective contact with long service life.
Following dimensions are standard:
Upto 60/80A 22.23 mm dia.-57 mm long II a 80/100A 30.16 mm dia.-57 mm long II b
Fuse Carriers.
These are of split design, therefore it only necessitates to loosen the fuse clips when replacing a fuse link. Fuse link can be withdrawn from the open end of the carrier half. Carrier housing is common for both 60A & 100A fuse links. Upgrading of cutout can be done simply by replacing with larger fuse clips.
Sealing:
The fuse carrier and fuse base unit have provision for wire sealing. An additional wire sealing arrangement is provided for the neutral.
Phase Protection:
A hinge type nylon shroud covers the incoming phase terminals thus reducing the possibility of accidental contact with live parts when wiring the outgoing terminal.
Interlocking:
Prior to removal of any component, the fuse carrier has to be withdrawn. This enables clear access to the neutral block and/or cable trough. This is an inbuilt safety feature.
Terminals:
The design and construction of the cutouts ensures terminals to be retained without the use of any fixing screws.
Adequate size serrated bores and pinching screws are provided for standard Copper or Aluminum and solid conductors of upto 35 sq. mm. on phase and neutral. The neutral/earth block of the cutout also has bores for two earth conductors and connection for a time switch wire. Cabling: The cable trough is designed for termination, suitable for PVC cables. In addition a small knockout is provided for an externally connected earth wire when using a PILCA cable.
Type Tests:
The cutout has been tested for the following Type Tests as per BS 7657:
Test for temperature rise at rated current.
Mechanical endurance (including repeat of test for temperature rise at rated current).
Overload test (including repeat of test for temperature rise at rated current, lightning impulse withstand voltage dry tests and power frequency withstand voltage dry tests).
Performance under short-circuit conditions and Terminal torque test.
Flammability test, Impact test, strength of sealing lugs.
Degree of protection test (Ip4x).
Routine Test
H.V. Test at 3.75 kV (rams) for one minute.
Insulation resistance test.
Mechanical insertion & withdrawal test.
Technical specifications
Type/Data
60/80A SP
100A SP
60/80A SPN
100A SPN
100A TPN
Rated Operating Voltage Ue
415V
415V
415V
415V
415V
Rated Operational Current in
60/80A
100A
60/80A
100A
100A
Rated Insulation Voltage Ui
660V
660V
660V
660V
660V
Rated Short Time Current Lcw
12 kA Peak 0.02 Sec
18 kA Peak 0.02 Sec
12 kA Peak 0.02 Sec
18 kA Peak 0.02 Sec
18 kA Peak 0.02 Sec
Impulse Voltage U imp
6 kV with 1.2/50µs waveform
6 kV with 1.2/50µs waveform
6 kV with 1.2/50µs waveform
6 kV with 1.2/50µs waveform
6 kV with 1.2/50µs 6 kV with 1.2/50µs waveform
Cable Size upto
35 sq. mm
35 sq. mm
35 sq. mm
35 sq. mm
35 sq. mm
Fuse Link Cartridge
As Per BS 1361 Type II a
As Per BS 1361 Type II b
As Per BS 1361 Type II a
As Per BS 1361 Type II b
As Per BS 1361 Type II b
Sealing Arrangement Provided
Yes
Yes
Yes
Yes
Yes
Tell us about your requirement
Price:
Quantity
Select Unit
50
100
200
250
500
1000+
Additional detail
Mobile number
Email
Confirm Your Requirement
Verification Code
Did not receive yet?
Resend OTP
Youre Done!
We have received your requirements and will reply shortly with the best price.
Products You May Like
Other Products in 'LV Electrical Cutouts' category